濟(jì)南電纜橋架: 橋架間距應(yīng)該如何設(shè)置?
電纜橋架水平安裝時(shí),支吊架之間距離適合在1.5米~2米,在轉(zhuǎn)彎處的支吊架間距應(yīng)為0.3米~0.6米,垂直安裝電纜橋架時(shí),支吊架間的距離不應(yīng)該超過2米。下面由濟(jì)南航豐實(shí)業(yè)的小編給大家介紹一下安裝電纜橋架間距要求的相關(guān)內(nèi)容。
When installing cable trays horizontally, the distance between supports and hangers should be suitable between 1.5 to 2 meters. The distance between supports and hangers at turns should be between 0.3 to 0.6 meters. When installing cable trays vertically, the distance between supports and hangers should not exceed 2 meters. Below, the editor from Jinan Hangfeng Industry will introduce the relevant content on the spacing requirements for installing cable trays.
電纜橋架與一般工藝管道平行鋪設(shè)時(shí),敷設(shè)間隔少400毫米,與工藝管道交叉敷設(shè)時(shí),安裝間距小為300毫米,電纜橋架與腐蝕氣體管道的平行間距少為500毫米,交叉間距小為500毫米。電纜橋架水平安裝時(shí),應(yīng)該按照載荷規(guī)范選擇支、吊架間距,距離不應(yīng)該大于2米。電纜橋架支、吊架的間距也要參考其產(chǎn)品性能參數(shù)說明來設(shè)置。
When the cable tray is laid parallel to the general process pipeline, the laying interval should be at least 400 millimeters. When cross laid with the process pipeline, the installation interval should be at least 300 millimeters. The parallel spacing between the cable tray and the corrosive gas pipeline should be at least 500 millimeters, and the cross spacing should be at least 500 millimeters. When installing cable trays horizontally, the spacing between supports and hangers should be selected according to the load specifications, and the optimal distance should not exceed 2 meters. The spacing between cable tray supports and hangers should also be set according to the product performance parameter specifications.

單層電纜橋架安裝時(shí),配套支吊架的間距不應(yīng)該大于2米,電纜橋架多層同時(shí)敷設(shè)時(shí),支吊架之間的距離應(yīng)該根據(jù)載荷進(jìn)行具體計(jì)算。電纜橋架與無保溫的熱力管道水平敷設(shè)時(shí),平行間距少為1米,交叉鋪設(shè)時(shí)的小間距應(yīng)為0.5米,電纜橋架與有保溫措施的熱力管道交叉敷設(shè)時(shí)距離小為300毫米,水平鋪設(shè)時(shí)距離少為500毫米。
When installing single-layer cable trays, the spacing between supporting brackets should not exceed 2 meters. When laying multiple layers of cable trays simultaneously, the distance between brackets should be calculated specifically based on the load. When cable trays are horizontally laid with uninsulated thermal pipelines, the parallel spacing should be at least 1 meter, and the minimum spacing when cross laid should be 0.5 meters. When cable trays are cross laid with insulated thermal pipelines, the minimum distance is 300 millimeters, and when horizontally laid, the distance is at least 500 millimeters.
本文由 濟(jì)南電纜橋架 友情奉獻(xiàn)。更多有關(guān)的知識(shí)請點(diǎn)擊: http://www.qianhe02.com 真誠的態(tài)度,為您提供為的服務(wù)。更多有關(guān)的知識(shí)我們將會(huì)陸續(xù)向大家奉獻(xiàn),敬請期待。
This article is dedicated to the friendship of Jinan cable tray. For more information, please click on: http://www.qianhe02.com Sincere attitude, providing you with comprehensive service. We will gradually contribute more relevant knowledge to everyone, please stay tuned.
下一篇:山東電纜橋架:電纜橋架與支架如何連接?
相關(guān)文章 / Recommended news
- 山東電纜橋架屋頂?shù)跹b:配件清單+標(biāo)準(zhǔn)化流程,新手也能零失誤
- 濟(jì)南電纜橋架安裝:200多斤600×200橋架,這樣吊裝又
- 山東電纜橋架定制:耐火板與防火型的核心區(qū)別,一文讀懂避坑指南
- 濟(jì)南電纜橋架選型誤區(qū):100×100規(guī)格加隔板難?航豐的方案破解施工難題
- 山東電纜橋架避坑!貫穿孔成火災(zāi)“隱形通道”?3步防火實(shí)操筑牢防線
- 濟(jì)南電纜橋架鋪設(shè)踩坑,層數(shù)、根數(shù)、限制,規(guī)范不看必返工
- 山東電纜橋架(鍍鋅款)接地線誤區(qū),接錯(cuò)必返工,規(guī)范要點(diǎn)一文說清
- 濟(jì)南電纜橋架線纜捆扎錯(cuò)了=埋隱患,4種規(guī)范方法,施工必看
- 山東不銹鋼橋架現(xiàn)場打孔避坑!4步標(biāo)準(zhǔn)流程,90%施工方少走彎路不損橋架
- 山東電纜橋架選型封神指南!記住3句話,70%工程方避開選型陷阱不花冤枉錢
陽極氧化鋁合金橋架
托盤式電纜橋架
梯式電纜橋架
梯式不銹鋼電纜橋架
深灰色金屬防火電纜橋架